Fibrodrain Load Testing
Fibrodrain FRP/GRP/Composite products are tested for different load classes: 2.5 tons, 5 tons, B125 (12.5 tons), C250 (25 tons), D400 (40 tons), E600 (60 tons) and F900 (90 tons).
Testing is done as per international and Indian standards: BS EN 124, IS 1726 and AASHTO. BS EN 124 is the globally accepted testing standard for manhole covers made of cast iron, ductile iron, FRP and other materials.
Products also undergo a Permanent Set Test – this means they are repeatedly loaded in a short time to check if the cover permanently deforms or loses strength.
Applicable Load Bearing
| Group | Class | Load | Installation Areas | Example |
|---|---|---|---|---|
| F900 | 90 Ton (900kN) | Areas imposing high wheel loads | Airports | |
| E600 | 60 Ton (600kN) | Areas imposing high wheel loads | Sea ports | |
| D400 | 40 Ton (400kN) | Carriageway of roads, including pedestrian ways and parking areas for all types of road vehicles | Truck roads | |
| C250 | 25 Ton (250kN) | Areas imposing high wheel loads | Cars | |
| B125 | 12.5 Ton (125kN) | Footways, pedestrian areas and areas with light duty | Cars | |
| A15 | 1.5 Ton (15kN) | Areas which can only be used by pedestrian and pedal cycles | Bikes & pedestrians |
DO's & DON'Ts
Ensure proper installation with complete civil support.
Use appropriate tools for handling.
Check load class before installation.
Regularly inspect drain covers for safety.
Do not place load before grouting is complete.
Avoid throwing or dragging the covers.
Do not exceed specified load limits.
Avoid installation in unsafe or wet conditions.